MTU Diesel Generator
Fukangsi Power , with the factory covering an area of 25,000M2, owns whole set of modern production equipments.
The company is capable of testing 8 individual generators simultaneously and 15KW-2000KW generator. Besides,
its integrated production capacity also extends to production design, molding, plastics processing, hardware stamping,
R&D of mechanical and electrical equipments, etc. The annual output reaches 4,000 sets.Foucs on Diesel Generator.
MTU Diesel Generators are ranging from 520kw up to 2400kw.
MTU Diesel Generator Ppowered by MTU engines,which is one of the world’s leading manufacturers of large diesel engines and complete propulsion systems. Together with MTU Onsite Energy, MTU is one of the leading brands of Tognum. Its product range is the widest and most modern in the sector. It covers diesel engines as well as complete propulsion systems for ships, for heavy agricultural, rail and military vehicles, and for the oil and gas industry. During a history spanning 100 years, the Tognum subsidiary MTU Friedrichshafen and its predecessors, including Maybach-Motorenbau GmbH in particular, have been responsible for repeated innovation and have continually been at the forefront of technological progress. MTU high-power Gen Sets, adopt electronic fuel injection diesel engine produced by world-famous German DAIMLER—CHRYSLER MTU. The history of MTU can be traced back to the 18th century of mechanical times. Now, following its good traditions, MTU comes out top among manufacturers of engines in the world owing to its unexampled advanced technology. The high quality of MTU’s engines is identical with the concept of reliably, advanced technology, high-class performance, environmental consciousness and long service life1. equiped with excellent MDEC digital management system, It can self-inspection, fault alarm instructions, records storage etc.2. lowest fuel consumption compare with other engines in the world.( 189g/kw.h least)3. longer service life compare with other engines in the world, every 30000 accumulated running hours for a periodical maintenance.4. the exhaust emission completely meet the German TALUFT standard, American CARB and EPA standard, EU-Ⅲstandard50HZ MTU Generating Set Data Sheet (1500RPM) | ||||||||
Model | Prime Power(kw) | Prime Power(kva) | Standby Power(kw) | Standby Power(kva) | MTU Engine Power | Engine Power (KW) | Dimension | (kg) |
FKS-M715 | 520 | 650 | 572 | 715 | 12V2000G25 | 638 | 4000*1750*2050 | 6600 |
FKS-M780 | 576 | 720 | 625 | 780 | 12V2000G63 | 680 | 4000*1750*2050 | 7000 |
FKS-M880 | 640 | 800 | 700 | 880 | 12V2000G65 | 765 | 4500*1800*2080 | 7200 |
FKS-M1000 | 720 | 900 | 800 | 1000 | 16V2000G25 | 891 | 6500*2600*2500 | 7600 |
FKS-M1100 | 800 | 1000 | 880 | 1100 | 16V2000G65 | 979 | 6500*2600*2500 | 8100 |
FKS-M1250 | 900 | 1125 | 1000 | 1250 | 18V2000G65 | 1100 | 6500*2600*2500 | 9000 |
FKS-M1375 | 1000 | 1250 | 1100 | 1375 | 12V4000G21R | 1212 | 6150*2150*2400 | 11500 |
FKS-M1400 | 1120 | 1400 | / | / | 12V4000G23R | 1205 | 6150*2150*2400 | 12000 |
FKS-M1650 | 1200 | 1500 | 1320 | 1650 | 12V4000G23 | 1575 | 6150*2150*2400 | 13500 |
FKS-M1800 | 1312 | 1640 | 1440 | 1800 | 12V4000G23 | 1575 | 6150*2150*2400 | 13500 |
FKS-M2000 | 1450 | 1813 | 1600 | 2000 | 12V4000G63 | 1750 | 6150*2150*2400 | 14000 |
FKS-M2250 | 1640 | 2050 | 1800 | 2250 | 16V4000G23 | 1978 | 6500*2600*2500 | 17000 |
FKS-M2500 | / | / | 2000 | 2500 | 16V4000G63 | 2185 | 6500*2600*2500 | 18000 |
FKS-M2750 | 2000 | 2500 | 2200 | 2750 | 20V4000G23 | 2420 | 8300*2950*2550 | 24000 |
FKS-M3000 | 2200 | 2750 | 2400 | 3000 | 20V4000G63 | 2670 | 8300*2950*2550 | 24500 |
FKS-M3300 | 2400 | 3000 | 2640 | 3300 | 20V4000G63L | 2850 | 8300*2950*2550 | 25000 |
Remarks:1). Above Gensets are based on 50HZ,1500 RPM, 400/230V, and other special voltage can be satisfied. 2). Requirements for Soundproof Canopy, ATS, Synchronizing Parallel Control panels etc are optional.3). Please email us for more detail data for engines, alternators and control systems.4). We observe the rights of data’s adjustment without prior notification.
How to select a suitable Generator for you?
The standby power rating is applicable for supplying emergency power for the duration ofnormal power interruption. No sustained overload capability is available for this rating.
This rating is applicable to installations served by a reliable normal utility source. This ratingis only applicable to variable loads with an average load factor of 80 percent of the standbyrating for a maximum of 200 hours of operation per year. In installations served by unreliableutility sources (where outages last longer and occur more frequently), where operationwill likely exceed 200 hours per year, the prime power rating should be applied.
Unlimited Running Time Prime PowerPrime power is available for an unlimited number of annual operating hours in variableload applications. Applications requiring any utility parallel operation at constantload are subject to running time limitations. In variable load applications, theaverage load factor should not exceed 70 percent of the Prime Power Rating.A 10 percent overload capability is available for a period of 1 hour within a 12 hourperiod of operation, but not to exceed 25 hours per year. The operating time at orabove the Prime Power Rating must not exceed 500 hours per year.
MTU Diesel Generator